Powerful Type Of Inverter
WIN-9(G\P)F Powerful Inverter
Power range
Voltage : 380V,680V Single-unit power : 1.5~1000kW
Application area
The ideal option of energy-saving device to match Compressor, extruding machine, blower, pump.
Main feature
- SPWM control.
- Stable operation with rated torque at low speed
- Fast adaptation to the varying load, high-efficiency voltage output, automatic regulation of V/F characteristics for variable load.
- Built-in RS-485 communication interface, fully supporting MODBUS Protocol.
- Advanced design of automatic torque compensation maximally optimizes the system’s performance.
- Presentable operation modes enable the machine to work more efficiently.
- 28 kinds of protecting and warning functions.
- Built in PID regulator which has more convenient regulating function.
- Online monitoring and adjusting function over variable parameters
Key |
Key Function |
LOCAL/REMOTE |
To switch between keypad control and remote control |
PRG |
To switch the function, monitor the function and display the default function code respectively in the status of setting, operating and fault. |
△ |
To change the function code and content in the status of setting, to change the output frequency in the status of operation. |
▽ |
|
SET |
To switch the function code and content in the status of setting, to read and store the function code and content. |
RUN |
To start the inverter’s operation in the condition of keypad control |
STOP/ RESET |
To stop the inverter’s operation in the condition of keypad operation. To stop the inverter’s operation in the event of fault. |
Terminal Function Table |
||||
Category |
Terminal |
Signal Function |
Function Description |
|
control signal |
FOR |
forward / stop |
to run forward while connected,to stop while disconnected |
multi-functional contact input(P035~039) |
X1 |
reverse / stop |
to run reversely while disconnected,to stop while disconnected |
||
X2 |
external fault input |
to fail while connected,to be in a normal state while disconnected |
||
X3 |
fault reset |
to reset while connected |
||
X4 |
multi-step speed speed command 1 |
effective while connected |
||
X5 |
multi-step speed speed command 2 |
effective while connected |
||
COM |
switch input command terminal |
— |
||
analog input signal |
+12V |
+12Vpower supply output |
analog command+12Vpower supply |
|
VG |
frequency input voltage |
0~10V/100% |
P042=0:VG effectiveP042=1:IG effective |
|
IG |
Frequency command input current |
4~20mA/100% |
||
GND |
connecting terminal of shielding sheath of signal wire |
— |
||
switch output signal |
TA2 |
operating signal(normally open contact ) |
to connect when operating |
multi-function contact output(P041) |
TC2 |
||||
TA1 |
fault contact output |
Between terminalTA1and C1. to fail while connected;to fail when terminal TB1and TC1 are disconnected |
multi-function contact output(P040) |
|
TB1 |
||||
TC1 |
||||
analog output signal |
FM |
frequency meter output |
0~10V/100%frequency |
multi-function analog value monitoring(P048) |
GND |
analog input command terminal |
|||
supplementary power supply |
P24V |
supplementary power supply |
+24V |
|
COM |
Item |
Specification |
||||||||||||||||
output |
Rated output voltage |
Maximum output voltage is same as power input voltage |
|||||||||||||||
output of adaptive motor (kW) |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
93 |
110 |
|
rated output current (A) |
4.8 |
6.2 |
8 |
14 |
18 |
27 |
34 |
41 |
52 |
65 |
80 |
96 |
128 |
165 |
180 |
224 |
|
output of adaptive motor (kW) |
132 |
160 |
185 |
200 |
220 |
245 |
280 |
315 |
355 |
400 |
500 |
560 |
630 |
710 |
800 |
1000 |
|
rated output current (A) |
260 |
302 |
340 |
380 |
450 |
470 |
530 |
605 |
660 |
750 |
940 |
1050 |
1200 |
1300 |
1500 |
1860 |
|
rating |
100%continuous |
||||||||||||||||
maximum overload current |
Series:150% 1minute,180% 6minute(Series:120% 1minute,140%18minute) |
||||||||||||||||
power input |
voltage / frequency |
three phase 380V (+10%~-15%) 50 / 60Hz±5% |
|||||||||||||||
control characteristics |
Frequency control range |
0~400Hz |
|||||||||||||||
Frequency precision |
digital command±0.01%(-10℃~+40℃) |
||||||||||||||||
frequency analysis setting |
digital command0.1Hz; analog command0.1Hz |
||||||||||||||||
Output frequency analysis |
0.1Hz |
||||||||||||||||
overload capacity |
Series:rated output current 150%1minute,Series:rated output current 120%1minute |
||||||||||||||||
Frequency setting signal |
0~+10V(20kΩ) 4~20mA(250Ω) |
||||||||||||||||
acceleration and deceleration time |
0.1~3600minute (independent setting of accelerating time and reaccelerating time) |
||||||||||||||||
braking torque |
additional braking resistance reaches125% |
||||||||||||||||
voltage / frequency characteristics |
15 kinds of fixed V/F characteristics optional and any V/F characteristics |
||||||||||||||||
protecting functions |
over voltage、under voltage、overload、thermionic relay、overheat、stall |
||||||||||||||||
environment |
ambient temperature / humidity |
-10℃ ~ +40℃ / 20~90% Rhino condensation |
|||||||||||||||
application area |
indoor(no corrosive odor,Altitude is less 1000 meters or less,no dust、no corrosive odor, no direct sunlight |
||||||||||||||||
vibration |
20Hz less than0.2g |
||||||||||||||||
protection level/cooling mode |
IP50 for 11-200kW ,the rest is IP20/forced air cooling |